Part Details Brand Cutout Height Cutout Width Display Type Number Of Digits Number of Phases Depth Meter Accuracy Minimum Temperature Maximum Temperature Maximum Measurement Measurement Range Meter Type Minimum Measurement Approvals Series
Schneider Electric PM5000 LCD Digital Power Meter, 92mm x 92mm, 3 Phase , ±0.5 % Accuracy Schneider Electric 92mm 92mm LCD - 3 90mm ±0.5 % -25°C - - - - - - PM5000
Schneider Electric Acti 9 iEM3000 LCD Digital Power Meter, 8-Digits, 3 Phase Schneider Electric - - LCD 8 3 69mm - -25°C 55°C 63 A, 99999999 MWh 0 → 99999999 MWh, Maximum of 63 A Electronic - CE, cULus, EN 50470-3, IEC 60529, IEC 61010, IEC 61036, IEC 61557-12, IEC 62053-21, IEC 62053-23, MID Conforming to EN 50470-1, MID Conforming to EN 50470-3, UL 61010-1 Acti 9 iEM3000
Schneider Electric PM5000 LCD Digital Power Meter, 92mm x 92mm, 3 Phase , ±0.5 % Accuracy Schneider Electric 92mm 92mm LCD - 3 90mm ±0.5 % -25°C - - - - - - PM5000
Schneider Electric PM5000 LCD Digital Power Meter, 92mm x 92mm, 3 Phase , ±0.5 % Accuracy Schneider Electric 92mm 92mm LCD - 3 90mm ±0.5 % -25°C - - - - - - PM5000
Schneider Electric Acti 9 iEM2000 LCD Digital Power Meter, 8-Digits, 1 Phase Schneider Electric - - LCD 8 1 64mm - -25°C +70°C 63 A, 65 Hz, 999999.99 kWh 0 → 999999.99 kWh, 45 → 65 Hz, Maximum of 63 A Electronic 0 kWh, 45 Hz CE, EN 50470-3, IEC 60529, IEC 62052-11, IEC 62052-31, IEC 62053-21, IEC 62053-23, IEC 62053-31, MID Conforming to EN 50470-1, MID Conforming to EN 50470-3, UL 94 Acti 9 iEM2000
Schneider Electric PM3200 LCD Digital Power Meter, 1, 3 Phase , 0.3 %, 0.5 % Accuracy Schneider Electric - - LCD - 1, 3 70mm 0.3 %, 0.5 % -25°C - - - - - - PM3200
Schneider Electric PM3200 LCD Digital Power Meter, 1, 3 Phase , 0.3 %, 0.5 % Accuracy Schneider Electric - - LCD - 1, 3 70mm 0.3 %, 0.5 % -25°C - - - - - - PM3200
Schneider Electric PM5000 LCD Digital Power Meter, 3 Phase Schneider Electric - - LCD - 3 72mm ±0.005 (Power Factor) %, ±0.05 (Frequency) %, ±0.5 (Active Energy) %, ±0.5 (Active Power) %, ±0.5 (Apparent Power) %, ±0.5 (Current) %, ±0.5 (Voltage) %, ±2 (Reactive Energy) % -25°C 70°C 400 (Phase and Neutral) V ac, 690 (Phase) V ac, 9 A, 65 Hz 10 mA → 9 A, 20 → 400 (Phase and Neutral) V ac, 35 → 690 (Phase) V ac, 45 → 65 Hz Electromechanical 20 (Phase and Neutral) V ac, 35 (Phase) V ac, 10 mA, 45 Hz CE Conforming to IEC 61010-1c, CULus Conforming to UL 61010-1, EN 50470-1, EN 50470-3, IEC 60529, IEC 61557-12, IEC 62053-22, IEC 62053-24 PM5000
Schneider Electric iEM3000 LCD Digital Power Meter, 10-Digits, Schneider Electric - - LCD 10 - 69mm - -25°C - - - - - - iEM3000
Schneider Electric PM5000 LCD Digital Power Meter, 3 Phase Schneider Electric - - LCD - 3 72mm ±0.005 (Power Factor) %, ±0.05 (Frequency) %, ±0.5 (Active Energy) %, ±0.5 (Active Power) %, ±0.5 (Apparent Power) %, ±0.5 (Current) %, ±0.5 (Voltage) %, ±2 (Reactive Energy) % -25°C +70°C 400 (Phase and Neutral) V ac, 690 (Phase) V ac, 9 A, 65 Hz 10 mA → 9 A, 20 → 400 (Phase and Neutral) V ac, 35 → 690 (Phase) V ac, 45 → 65 Hz Electromechanical 20 (Phase and Neutral) V ac, 35 (Phase) V ac, 10 mA, 45 Hz CE Conforming to IEC 61010-1c, CULus Conforming to UL 61010-1, EN 50470-1, EN 50470-3, EN 55022, IEC 60529, IEC 61000-4-2, IEC 61000-4-8, IEC 61557-12, IEC 62053-22, IEC 62053-24 PM5000
Schneider Electric PM1000 LCD Digital Power Meter, 95mm x 90mm, 10-Digits, 3 Phase Schneider Electric 95mm 90mm LCD 10 3 69mm - -25°C - - - - - - PM1000
Com'X 200 PowerLogic server/data logger Schneider Electric - - LED - - 69mm - -25°C +60°C - - - - CE, C-Tick, EN 60950, EN 61010-1 -
Schneider Electric Acti 9 iEM2000 LCD Digital Power Meter, 8-Digits, 1 Phase Schneider Electric - - LCD 8 1 64mm - -25°C +70°C 63 A, 65 Hz, 999999.99 kWh 0 → 999999.99 kWh, 45 → 65 Hz, Maximum of 63 A Electronic 0 kWh, 45 Hz CE, EN 50470-3, IEC 60529, IEC 62052-11, IEC 62052-31, IEC 62053-21, IEC 62053-23, IEC 62053-31, UL 94 Acti 9 iEM2000
Schneider Electric Acti 9 iEM3000 LCD Digital Power Meter, 8-Digits, 3 Phase Schneider Electric - - LCD 8 3 69mm - -25°C 55°C 63 A, 99999999 MWh 0 → 99999999 MWh, Maximum of 63 A Electronic - CE, cULus, EN 50470-3, IEC 60529, IEC 61010, IEC 61036, IEC 61557-12, IEC 62053-21, IEC 62053-23, MID Conforming to EN 50470-1, MID Conforming to EN 50470-3, UL 61010-1 Acti 9 iEM3000
Schneider Electric Acti 9 iEM3000 LCD Digital Power Meter, 9-Digits, 3 Phase Schneider Electric - - LCD 9 3 69.3mm - -25°C +55°C 125 A, 99999999.9 kWh 0 → 99999999.9 kWh, Maximum of 125 A Electronic 0kWh CE, cULus, EN 50470-3, IEC 60529, IEC 61010, IEC 61036, IEC 61557-12, IEC 62053-21, IEC 62053-23, MID Conforming to EN 50470-1, MID Conforming to EN 50470-3, UL 61010-1 Acti 9 iEM3000
Schneider Electric Acti 9 iEM3000 LCD Digital Power Meter, 9-Digits, 3 Phase Schneider Electric - - LCD 9 3 69.3mm - -25°C 55°C 125 A, 99999999.9 kWh 0 → 99999999.9 kWh, Maximum of 125 A Electronic 0kWh CE, cULus, EN 50470-3, IEC 60529, IEC 61010, IEC 61036, IEC 61557-12, IEC 62053-21, IEC 62053-23, MID Conforming to EN 50470-1, MID Conforming to EN 50470-3, UL 61010-1 Acti 9 iEM3000
Schneider Electric LED Gateway Server, Schneider Electric - - LED - - 69mm - -25°C 70°C - - - - CE, C-Tick, CUL, EN 60950, EN 61010-1, UL, UL 508, UL 60950 -
Schneider Electric PM5000 LCD Digital Power Meter, 92mm x 92mm, 3 Phase , ±0.5 % Accuracy Schneider Electric 92mm 92mm LCD - 3 90mm ±0.5 % -25°C - - - - - - PM5000
Schneider Electric PM8000 LCD Digital Power Meter, Schneider Electric - - LCD - - 27mm - -25°C +60°C - - - - IEC, IEC 60529 PM8000
Schneider Electric PM8000 LCD Digital Power Meter, 3 Phase Schneider Electric - - LCD - 3 77.5mm ±0.1 (Current) %, ±0.1 (Voltage) %, ±0.2 (Active Energy) % -25°C 70°C 400 (Phase and Neutral) V ac, 690 (Phase) V ac, 10 A, 69 Hz 100 → 690 (Phase) V ac, 42 → 69 Hz, 50 mA → 10 A, 57 → 400 (Phase and Neutral) V ac Electromechanical 100 (Phase) V ac, 57 (Phase and Neutral) V ac, 42 Hz, 50 mA CE, CSA C22.2 No 61010-1, CULus, EN 61010-1, IEC 60529, IEC 61010-1, IEC 61557-12, IEC 62052-11, IEC 62053-22, IEC 62053-24, N998, UL 61010-1 PM8000
Check Our Stock Volumes
Enter the quantity you require and click 'Check'. Stock information was updated at