Bosch Rexroth Ten series 10bar 1in Hydraulic Filter, 62L/min max, 10μm filtration size

RS Stock No.: 869-6933Brand: Bosch RexrothManufacturers Part No.: R928041273IMPA: 0
brand-logo
View all in Hydraulic Filters

Technical Document

Specifications

Connection Thread

G 1

Thread Standard

G

Filtration Size

10µm

Thread Size

1in

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

+100°C

Maximum Flow Rate

62L/min

Maximum Operating Pressure

10bar

Manufacturer Series

Ten

Country of Origin

Germany

Product details

C60N C-curve circuit breakers

Rated current: 0.5 A → 63 A at 30 °C
Nominal load voltage: 230 / 400 VAC
Fast breaking: the contact breaking speed is independent from operator action.
Neutral contact: early-break late-make in relation to phases.
Trip curve: trips between 5 and 10 in.
Connection: cage clamp for 25 mm2 cables up to 25 A and 35 mm2 cables for in. from 32 → 63 A
IMQ mark for protection from 6 → 25 A
Breaking capacity IEC EN 60898 (IEC 23-3 4th ed.) 6000 A
Breaking capacity IEC EN 60947-2 10 kA.

Merlin Gerin – Type B & C, 10kA Breaking Capacity MCBs

Miniature Circuit Breakers; Contact Position indicated by switch levers

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

AED 897.00

Each (ex VAT)

AED 941.85

Each (inc VAT)

Bosch Rexroth Ten series 10bar 1in Hydraulic Filter, 62L/min max, 10μm filtration size

AED 897.00

Each (ex VAT)

AED 941.85

Each (inc VAT)

Bosch Rexroth Ten series 10bar 1in Hydraulic Filter, 62L/min max, 10μm filtration size
Stock information temporarily unavailable.

Technical Document

Specifications

Connection Thread

G 1

Thread Standard

G

Filtration Size

10µm

Thread Size

1in

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

+100°C

Maximum Flow Rate

62L/min

Maximum Operating Pressure

10bar

Manufacturer Series

Ten

Country of Origin

Germany

Product details

C60N C-curve circuit breakers

Rated current: 0.5 A → 63 A at 30 °C
Nominal load voltage: 230 / 400 VAC
Fast breaking: the contact breaking speed is independent from operator action.
Neutral contact: early-break late-make in relation to phases.
Trip curve: trips between 5 and 10 in.
Connection: cage clamp for 25 mm2 cables up to 25 A and 35 mm2 cables for in. from 32 → 63 A
IMQ mark for protection from 6 → 25 A
Breaking capacity IEC EN 60898 (IEC 23-3 4th ed.) 6000 A
Breaking capacity IEC EN 60947-2 10 kA.

Merlin Gerin – Type B & C, 10kA Breaking Capacity MCBs

Miniature Circuit Breakers; Contact Position indicated by switch levers