Technical Document
Specifications
Brand
EuchnerPower to Lock / Unlock
Power to Unlock
Supply Voltage
24V ac/dc
Series
TZ1
Actuator Included
No
Safety Contacts
NO/NC
Conduit Entry
PG11
Housing Material
Metal
Depth
31mm
Width
110mm
Length
110mm
Country of Origin
Germany
Product details
TZ1.E024M - Metal Encapsulated, Electromagnetic Locking Device
1000 N retention in locked position
Actuator head can be converted into 4 directions of travel
Actuator head fitted on right or left side of safety switch
Rear opening on actuator head enables removal of contaminants
Switching element for monitoring loop and safety circuit each with 1 positive break contact and 1 NO
Auxiliary lock on front
Please order actuator separately
This metal encapsulated safety switch is used to monitor moveable separating protective devices (e.g. sliding or rotating doors). The protective device is kept shut and locked by the safety switch until risk of injury from potentially dangerous machine parts (e.g. run-on movements) has passed.
The protective device is released by applying voltage to the magnets fitted in the safety switch. The locking status of the doors is monitored at all times.
The two LED displays ensure that it is easy to see the location of the safety and monitoring switching element at all times (even from long distances).
Approvals
BG; CSA; SAQ; SUVA and UL
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical Document
Specifications
Brand
EuchnerPower to Lock / Unlock
Power to Unlock
Supply Voltage
24V ac/dc
Series
TZ1
Actuator Included
No
Safety Contacts
NO/NC
Conduit Entry
PG11
Housing Material
Metal
Depth
31mm
Width
110mm
Length
110mm
Country of Origin
Germany
Product details
TZ1.E024M - Metal Encapsulated, Electromagnetic Locking Device
1000 N retention in locked position
Actuator head can be converted into 4 directions of travel
Actuator head fitted on right or left side of safety switch
Rear opening on actuator head enables removal of contaminants
Switching element for monitoring loop and safety circuit each with 1 positive break contact and 1 NO
Auxiliary lock on front
Please order actuator separately
This metal encapsulated safety switch is used to monitor moveable separating protective devices (e.g. sliding or rotating doors). The protective device is kept shut and locked by the safety switch until risk of injury from potentially dangerous machine parts (e.g. run-on movements) has passed.
The protective device is released by applying voltage to the magnets fitted in the safety switch. The locking status of the doors is monitored at all times.
The two LED displays ensure that it is easy to see the location of the safety and monitoring switching element at all times (even from long distances).
Approvals
BG; CSA; SAQ; SUVA and UL