RS PRO DEF STAN Multi-Core Industrial Cable, 4 Cores, 0.5 mm² 20 AWG, Unscreened, 100 m, Black Polyvinyl Chloride Sheath
RS Stock No. 236-9233
Brand RS Pro
- American Wire Gauge: 20AWG
- Category Link: https://ae.rsdelivers.com/browse/electrical-automation-cables/cables-wires/electrical-power-industrial-cables/control-cable
- Conductor Material: Brass
AED 830.94
in stock now
RS PRO DEF STAN Multi-Core Industrial Cable, 4 Cores, 0.5 mm², Unscreened, 25 m, Black Polyvinyl Chloride Sheath
RS Stock No. 236-9234
Brand RS Pro
- Cable CSA: 0.5 mm²
- Category Link: https://ae.rsdelivers.com/browse/electrical-automation-cables/cables-wires/electrical-power-industrial-cables/control-cable
- Number of Cores: 4
AED 187.96
in stock now
RS PRO DEF STAN Multi-Core Industrial Cable, 4 Cores, 0.5 mm², Screened, 100 m, Black Polyvinyl Chloride Sheath
RS Stock No. 236-9235
Brand RS Pro
- Cable Length: 100m
- Minimum Operating Temperature: -15°C
- Super Section: Electrical Power & Industrial Cables
AED 1.435.38
in stock now
RS PRO DEF STAN Multi-Core Industrial Cable, 4 Cores, 0.5 mm², Screened, 500 m, Black Polyvinyl Chloride Sheath
RS Stock No. 236-9237
Brand RS Pro
- Jacket Material: Polyvinyl Chloride
- Minimum Operating Temperature: -40°C
- Section: Cables & Wires
AED 6.131.78
in stock now
RS PRO DEF STAN Multi-Core Industrial Cable, 4 Cores, 0.22 mm², Unscreened, 25 m, Black Polyvinyl Chloride Sheath
RS Stock No. 236-9261
Brand RS Pro
- Conductor Material: Tin Copper Wire
- Fire Behaviour: Flame Retardant
- Section: Cables & Wires
AED 107.01
in stock now
RS PRO DEF STAN Multi-Core Industrial Cable, 4 Cores, 0.22 mm², Screened, 25 m, Black Polyvinyl Chloride Sheath
RS Stock No. 236-9263
Brand RS Pro
- Cable CSA: 0.22 mm²
- Jacket Colour: Black
- Jacket Material: Polyvinyl Chloride
AED 183.52
in stock now
RS PRO DEF STAN Multi-Core Industrial Cable, 4 Cores, 0.22 mm², Screened, 500 m, Black Polyvinyl Chloride Sheath
RS Stock No. 236-9264
Brand RS Pro
- Cable CSA: 0.22 mm²
- Jacket Material: Polyvinyl Chloride
- Product Type: Multi-Core Industrial Cable
AED 3.353.37
in stock now
RS PRO DEF STAN Multi-Core Industrial Cable, 4 Cores, 0.5 mm², Screened, 25 m, Black Polyvinyl Chloride Sheath
RS Stock No. 236-9236
Brand RS Pro
- Conductor Material: Tin Copper Wire
- Conductor Type: Solid
- Outside Diameter: 11 mm
AED 341.94
in stock now
RS PRO DEF STAN Multi-Core Industrial Cable, 4 Cores, 0.22 mm², Unscreened, 100 m, Black Polyvinyl Chloride Sheath
RS Stock No. 236-9260
Brand RS Pro
- Category: Control Cable
- Jacket Colour: Black
- Jacket Material: Polyvinyl Chloride
AED 406.65
in stock now
RS PRO DEF STAN Multi-Core Industrial Cable, 4 Cores, 0.22 mm², Screened, 100 m, Black Polyvinyl Chloride Sheath
RS Stock No. 236-9262
Brand RS Pro
- Category: Control Cable
- Conductor Material: Tin Copper Wire
- Maximum Operating Temperature: 120°C
AED 680.39
in stock now
RS PRO Control Cable, 4 Cores, 0.19 mm², Unscreened, 100 m, White Polyvinyl Chloride Sheath
RS Stock No. 820-0185
Brand RS Pro
- Jacket Colour: White
- Minimum Operating Temperature: -50°C
- Section: Cables & Wires
AED 392.72
in stock now
RS PRO LiYY Control Cable, 4 Cores, 0.34 mm² 22 AWG, Unscreened, 100 m, Grey Polyvinyl Chloride Sheath
RS Stock No. 136-8198
Brand RS Pro
- Armoured: Yes
- Category: Control Cable
- Conductor Type: Stranded
AED 707.47
in stock now
RS PRO LiYY Control Cable, 4 Cores, 0.5 mm² 20 AWG, Unscreened, 100 m, Grey Polyvinyl Chloride Sheath
RS Stock No. 136-8202
Brand RS Pro
- Conductor Material: Bare Copper
- Number of Cores: 4
- Voltage: 300 V
AED 893.46
in stock now
RS PRO Bus Data Cable, 4 Cores, 0.8 mm² 20 AWG, Screened, 100 m, Green Polyvinyl Chloride Sheath
RS Stock No. 136-8221
Brand RS Pro
- American Wire Gauge: 20AWG
- Conductor Material: Bare Copper
- Screened/Unscreened: Screened
AED 1.093.11
in stock now
RS PRO DEF STAN Multi-Core Industrial Cable, 12 Cores, 0.5 mm², Screened, 50 m, Black Polyvinyl Chloride Sheath
RS Stock No. 236-9223
Brand RS Pro
- Cable Length: 50m
- Conductor Type: Solid
- Number of Cores: 12
AED 1.501.28
in stock now
RS PRO DEF STAN Multi-Core Industrial Cable, 12 Cores, 0.5 mm², Screened, 500 m, Black Polyvinyl Chloride Sheath
RS Stock No. 236-9224
Brand RS Pro
- Conductor Material: Tin Copper Wire
- Jacket Colour: Black
- Minimum Operating Temperature: -40°C
AED 10.983.00
in stock now
RS PRO 2XX0 B Control Cable, 6 Cores, 0.22 mm², Screened, 100 m, White Polyvinyl Chloride Sheath
RS Stock No. 136-8142
Brand RS Pro
- Cable Length: 100m
- Minimum Operating Temperature: -10°C
- Number of Cores: 6
AED 587.59
in stock now
RS PRO LiYY Control Cable, 3 Cores, 0.34 mm² 22 AWG, Unscreened, 100 m, Grey Polyvinyl Chloride Sheath
RS Stock No. 136-8197
Brand RS Pro
- Cable CSA: 0.34 mm²
- Category: Control Cable
- Jacket Colour: Grey
AED 621.91
in stock now
RS PRO LiYY Control Cable, 3 Cores, 0.5 mm² 20 AWG, Unscreened, 100 m, Grey Polyvinyl Chloride Sheath
RS Stock No. 136-8201
Brand RS Pro
- Cable CSA: 0.5 mm²
- Conductor Type: Stranded
- Jacket Colour: Grey
AED 738.59
in stock now
RS PRO LiYY Control Cable, 2 Cores, 0.5 mm² 20 AWG, Unscreened, 100 m, Grey Polyvinyl Chloride Sheath
RS Stock No. 136-8200
Brand RS Pro
- American Wire Gauge: 20AWG
- Category Link: https://ae.rsdelivers.com/browse/electrical-automation-cables/cables-wires/electrical-power-industrial-cables/control-cable
- Screened/Unscreened: Unscreened
AED 570.06
in stock now
RS PRO 45 A EV Charging Cable 50 m
RS Stock No. 222-1597
Brand RS Pro
- Category: EV Charging Cable
- Outside Diameter: 16.5 mm
- Product Type: EV Charging Cable
AED 3.241.07
in stock now
RS PRO 58 A EV Charging Cable 50 m
RS Stock No. 245-6410
Brand RS Pro
- Cross Sectional Area: 10 mm²
- Number of Cores: 5
- Outside Diameter: 23.4 mm
AED 7.883.94
in stock now
RS PRO 45 A EV Charging Cable 50 m
RS Stock No. 222-1598
Brand RS Pro
- Number of Cores: 3
- Product Type: EV Charging Cable
- Voltage: 600/1000V
AED 2.822.51
in stock now
Alpha Wire 6520 Cable, 4 Cores, 4 mm² 12 AWG, Screened, 100 ft, Grey Polyvinyl Chloride Sheath
RS Stock No. 010-5911
Brand Alpha Wire
- Conductor Type: Stranded
- Number of Cores: 4
- Screened/Unscreened: Screened
AED 5.788.27
in stock now
...
What is armoured cable 4 core?
What are common uses for armoured cable 4 core?
How do I choose the right size and rating of armoured cable 4 core?
- Conductor cross-sectional area (1.5mm², 2.5mm², 4mm², 6mm², etc.) which determines current capacity
- Voltage rating (typically 300/500V or 600/1000V for armoured cables)
- Outer sheath material (PVC) and any variants (LSZH for low smoke zero halogen environments)
- Temperature rating of the insulation (commonly 70°C for PVC insulated conductors)
- Installation environment (indoors, outdoors, underground direct burial, or in conduit)
What are the differences between armoured cable 4 core and other types of cables?
: Armoured cables have galvanised steel wire armour (SWA) that shields conductors from mechanical damage, vibration, and impact, making them suitable for outdoor or underground use. - Conductor configuration: 4-core cables carry four insulated conductors, which can be used for single-phase or three-phase circuits, often with earth/neutral depending on the circuit design.
- Outer sheath: They feature a robust outer sheath (usually PVC or LSZH) designed for environmental exposure and moisture resistance.
- Applications: Ideal for fixed installations, industrial environments, and direct burial in compliant installations; non-armoured cables are typically used for internal wiring and applications with less physical risk.
How do I install and terminate armoured cable 4 core safely?
- Power off at the main supply and verify zero voltage before handling any conductors.
- Plan the route to avoid sharp bends and physical damage; maintain the minimum bending radius specified by the manufacturer.
- Use appropriate protective conduits or trays if required by the installation environment and ensure the armoured layer remains intact during routing.
- Prepare terminations with correctly rated glands and end caps, ensuring continuity of the armour to earth if required by the installation standard.
- Secure the cable with clamps and avoid over-tightening; ensure the armour is not damaged at entry points.
- Make sure joints and terminations are moisture-tight and suitable for outdoor or underground use if applicable.
- Test insulation resistance and continuity after installation, and seal any access points to protect against moisture ingress.
Can armoured cable 4 core be buried directly, and what are the requirements?
- The cable is rated for direct burial and installed at a depth that complies with local regulations.
- There is a suitable warning tape and protection against sharp objects or heavy loads above the burial route.
- The outer sheath and armour are compatible with underground exposure to moisture, soil minerals, and temperature variations.
- All joints and terminations are properly sealed and the glands are rated for outdoor or underground use.
What accessories do I need with armoured cable 4 core?
- Compression glands or armour glands designed for armoured cables to ensure a secure and earth-continuity-friendly termination.
- End caps or protective caps to seal the open ends for moisture protection.
- Cable clips, straps, and saddles for routing and fixing along walls or ducts.
- Jointing kits or repair sleeves for extending or repairing damaged sections of armour or conductor insulation.
- Conduit, trunking, or ducting if required by the installation environment, plus sealing compounds for moisture control.
What standards and safety considerations apply to armoured cable 4 core?
- Conformance to regional electrical wiring standards (for example, BS EN, IEC, or national variants) for fixed installations and protections.
- Proper insulation insulation voltage rating, temperature rating, and moisture resistance for outdoor and underground use.
- Correct sizing for current, voltage, and fault conditions, with adequate protection devices (fuse or breaker) in the distribution path.
- Use of appropriate glands, connectors, and termination methods to maintain earth continuity and mechanical protection.
- Regular inspection and testing to ensure integrity of the armour and insulation over time, especially in harsh environments.