Technical Document
Specifications
Brand
ABBMonitoring Application
Phase
Electrical Phase
3
Contact Configuration
DPDT
Mounting Type
DIN Rail
Phase Sensitivity
Phase Failure, Phase Imbalance, Phase Sequence
Time Delay
0.1 → 30 s, 0s
Series
CM-PAS
Height
85.6mm
Length
103.7mm
Operating Temperature Range
+60°C
Terminal Type
Screw
Minimum Operating Temperature
-25°C
Width
22.5mm
Maximum Operating Temperature
+60°C
Dimensions
103.7 x 22.5 x 85.6mm
Country of Origin
Germany
Product details
CM-PAS Three-Phase Monitoring Relays
The CM-PAS.x1 are monitoring relays for three-phase mains. They monitor the phase parameters phase sequence, phase failure and phase unbalance. The threshold value for phase unbalance is adjustable
Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance
Threshold value for phase unbalance adjustable as absolute value
Tripping delay can be adjusted or switched off by means of a logarithmic scale
ON-delayed tripping delay
Powered by the measuring circuit
True RMS measuring principle
2 c/o (SPDT) contacts
3 LEDs for status indication
AED 1,067.27
AED 1,067.27 Each (ex VAT)
AED 1,120.63
AED 1,120.63 Each (inc. VAT)
1
AED 1,067.27
AED 1,067.27 Each (ex VAT)
AED 1,120.63
AED 1,120.63 Each (inc. VAT)
1
Stock information temporarily unavailable.
Please check again later.
| Quantity | Unit price |
|---|---|
| 1 - 4 | AED 1,067.27 |
| 5 - 9 | AED 1,013.88 |
| 10 - 24 | AED 960.49 |
| 25 - 49 | AED 907.25 |
| 50+ | AED 853.76 |
Technical Document
Specifications
Brand
ABBMonitoring Application
Phase
Electrical Phase
3
Contact Configuration
DPDT
Mounting Type
DIN Rail
Phase Sensitivity
Phase Failure, Phase Imbalance, Phase Sequence
Time Delay
0.1 → 30 s, 0s
Series
CM-PAS
Height
85.6mm
Length
103.7mm
Operating Temperature Range
+60°C
Terminal Type
Screw
Minimum Operating Temperature
-25°C
Width
22.5mm
Maximum Operating Temperature
+60°C
Dimensions
103.7 x 22.5 x 85.6mm
Country of Origin
Germany
Product details
CM-PAS Three-Phase Monitoring Relays
The CM-PAS.x1 are monitoring relays for three-phase mains. They monitor the phase parameters phase sequence, phase failure and phase unbalance. The threshold value for phase unbalance is adjustable
Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance
Threshold value for phase unbalance adjustable as absolute value
Tripping delay can be adjusted or switched off by means of a logarithmic scale
ON-delayed tripping delay
Powered by the measuring circuit
True RMS measuring principle
2 c/o (SPDT) contacts