Technical Document
Specifications
Brand
Broyce ControlMonitoring Application
Phase, Voltage
Electrical Phase
3
Voltage Sensing Range
243 → 540V ac
Contact Configuration
DPDT
Voltage Sensitivity
Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Failure, Phase Sequence
Time Delay
0.2 → 10s
Series
L
Maximum Operating Temperature
+60°C
Width
17.5mm
Number of Poles
2
Length
66.5mm
Dimensions
66.5 x 17.5 x 89mm
Operating Temperature Range
+60°C
Maximum Voltage Sensed
540V
Terminal Type
Screw
Special Features
Microprocessor Based, Detects Incorrect Phase Sequence, Phase Loss And Neutral Loss, Adjustment For Under Voltage Trip Level, Adjustment For Time Delay
Minimum Operating Temperature
-20°C
Height
89mm
Country of Origin
United Kingdom
Product details
LPRD/2 Phase Failure, Phase Sequence, Under Voltage plus Restart Delay
Broyce Controls L-Series signal conditioners use a QR barcode marking method allowing direct access to all technical data sheets, ensuring correct information is always at your finger tips!
Features and Benefits
Compact 17.5 mm DIN Rail housing
Microprocessor based
True R.M.S. monitoring measuring phase to phase (three wire) or phase to neutral (4-wire) voltages
Selectable nominal voltages to suit most popular three wire or 4-wire supply voltages
Monitors own supply and detects an Under voltage condition on one or more phases
Detects incorrect phase sequence, phase loss and neutral loss1
Adjustment for Under voltage trip level
Adjustment for Restart delay
Adjustment for time delay
DPDT relay output 5A
Green LED indication for supply status
Red LED indication for relay status
Approvals
UL Certification
Broyce Monitor Relays
Stock information temporarily unavailable.
Please check again later.
AED 455.95
Each (ex VAT)
AED 478.75
Each (inc. VAT)
1
AED 455.95
Each (ex VAT)
AED 478.75
Each (inc. VAT)
1
Technical Document
Specifications
Brand
Broyce ControlMonitoring Application
Phase, Voltage
Electrical Phase
3
Voltage Sensing Range
243 → 540V ac
Contact Configuration
DPDT
Voltage Sensitivity
Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Failure, Phase Sequence
Time Delay
0.2 → 10s
Series
L
Maximum Operating Temperature
+60°C
Width
17.5mm
Number of Poles
2
Length
66.5mm
Dimensions
66.5 x 17.5 x 89mm
Operating Temperature Range
+60°C
Maximum Voltage Sensed
540V
Terminal Type
Screw
Special Features
Microprocessor Based, Detects Incorrect Phase Sequence, Phase Loss And Neutral Loss, Adjustment For Under Voltage Trip Level, Adjustment For Time Delay
Minimum Operating Temperature
-20°C
Height
89mm
Country of Origin
United Kingdom
Product details
LPRD/2 Phase Failure, Phase Sequence, Under Voltage plus Restart Delay
Broyce Controls L-Series signal conditioners use a QR barcode marking method allowing direct access to all technical data sheets, ensuring correct information is always at your finger tips!
Features and Benefits
Compact 17.5 mm DIN Rail housing
Microprocessor based
True R.M.S. monitoring measuring phase to phase (three wire) or phase to neutral (4-wire) voltages
Selectable nominal voltages to suit most popular three wire or 4-wire supply voltages
Monitors own supply and detects an Under voltage condition on one or more phases
Detects incorrect phase sequence, phase loss and neutral loss1
Adjustment for Under voltage trip level
Adjustment for Restart delay
Adjustment for time delay
DPDT relay output 5A
Green LED indication for supply status
Red LED indication for relay status
Approvals
UL Certification