Technical Document
Specifications
Brand
Carlo GavazziBody Style
Barrel
Output Type
NAMUR
Detection Range
15 mm
Terminal Type
Cable
IP Rating
IP67
Supply Voltage
8.2 V dc, 7 → 9 V dc
Length
71mm
Maximum dc Voltage
9V
Mounting Type
Non Flush
Switching Current
9.35 mA
Shielding
Partial
Housing Material
Stainless Steel
Maximum Operating Temperature
+70°C
Minimum Operating Temperature
-25°C
Reverse Polarity Protection
Yes
Country of Origin
Malta
Product details
Type IA, Thermoplastic Polyester Housing
These proximity sensors have been manufactured in a thermoplastic polyester housing and come in either long or short versions. Various size housings are available including M12, M18 and M30. There are also the options of a 2 meter cable or M12 plug termination.
Features:
Euronorm thermoplastic polyester housing, cylindrical
Short or long versions
Diameter: M12, M18, M30
Sensing distance: 2 to 15 mm
Output: NAMUR EN 50 227
Protection: Reverse polarity
LED-indication
2 m cable or M12 plug
Standards
EN 50 227 and EN 60 947-5-2
Carlo Gavazzi Inductive Proximity Sensors
P.O.A.
1
P.O.A.
1
Stock information temporarily unavailable.
Please check again later.
Technical Document
Specifications
Brand
Carlo GavazziBody Style
Barrel
Output Type
NAMUR
Detection Range
15 mm
Terminal Type
Cable
IP Rating
IP67
Supply Voltage
8.2 V dc, 7 → 9 V dc
Length
71mm
Maximum dc Voltage
9V
Mounting Type
Non Flush
Switching Current
9.35 mA
Shielding
Partial
Housing Material
Stainless Steel
Maximum Operating Temperature
+70°C
Minimum Operating Temperature
-25°C
Reverse Polarity Protection
Yes
Country of Origin
Malta
Product details
Type IA, Thermoplastic Polyester Housing
These proximity sensors have been manufactured in a thermoplastic polyester housing and come in either long or short versions. Various size housings are available including M12, M18 and M30. There are also the options of a 2 meter cable or M12 plug termination.
Features:
Euronorm thermoplastic polyester housing, cylindrical
Short or long versions
Diameter: M12, M18, M30
Sensing distance: 2 to 15 mm
Output: NAMUR EN 50 227
Protection: Reverse polarity
LED-indication
2 m cable or M12 plug
Standards
EN 50 227 and EN 60 947-5-2