Dold Voltage Monitoring Relay, 3 Phase, DPDT, DIN Rail

RS Stock No.: 291-3150Brand: DoldManufacturers Part No.: IL9079.12/002 3AC230/400V 0.55-1.05UN 0.2-2S
brand-logo
View all in Monitoring Relays

Technical Document

Specifications

Brand

Dold

Monitoring Application

Voltage

Electrical Phase

3

Contact Configuration

DPDT

Voltage Sensitivity

Undervoltage

Mounting Type

DIN Rail

Time Delay

0.2 → 2s

Series

IL 9079

Dimensions

59 x 35 x 90mm

Height

90mm

Length

59mm

Operating Temperature Range

+60°C

Minimum Operating Temperature

-20°C

Width

35mm

Maximum Operating Temperature

+60°C

Country of Origin

Germany

Product details

Undervoltage relay for detecting short interruptions, IL9079

The IL9079 is an undervoltage relay for detecting short interruptions. Enclosure version for the IL 9079 has a depth of 59 mm. Terminals are at the bottom for installation systems and industrial distribution systems according to DIN 43 880.

Features & Benefits
Detecting undervoltage, short interruptions or phase loss in 3 phase systems
Prevents undefined states in the event of voltage errors
Detects short interruptions of 20 ms
Adjustable fallback value of 0.55 → 1.05 UN
Adjustable reactivation delay
Configurable reactivation Block
Also for single phase connections
Relay output, 2 changeovers
35 mm overall width
In accordance with IEC 255, VDE 0435 Section 303
Green LED indicates for closed contact
Optionally for 3p3w systems
Manual reset is possible with external circuit

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

AED 1,248.00

Each (ex VAT)

AED 1,310.40

Each (inc. VAT)

Dold Voltage Monitoring Relay, 3 Phase, DPDT, DIN Rail

AED 1,248.00

Each (ex VAT)

AED 1,310.40

Each (inc. VAT)

Dold Voltage Monitoring Relay, 3 Phase, DPDT, DIN Rail
Stock information temporarily unavailable.

Technical Document

Specifications

Brand

Dold

Monitoring Application

Voltage

Electrical Phase

3

Contact Configuration

DPDT

Voltage Sensitivity

Undervoltage

Mounting Type

DIN Rail

Time Delay

0.2 → 2s

Series

IL 9079

Dimensions

59 x 35 x 90mm

Height

90mm

Length

59mm

Operating Temperature Range

+60°C

Minimum Operating Temperature

-20°C

Width

35mm

Maximum Operating Temperature

+60°C

Country of Origin

Germany

Product details

Undervoltage relay for detecting short interruptions, IL9079

The IL9079 is an undervoltage relay for detecting short interruptions. Enclosure version for the IL 9079 has a depth of 59 mm. Terminals are at the bottom for installation systems and industrial distribution systems according to DIN 43 880.

Features & Benefits
Detecting undervoltage, short interruptions or phase loss in 3 phase systems
Prevents undefined states in the event of voltage errors
Detects short interruptions of 20 ms
Adjustable fallback value of 0.55 → 1.05 UN
Adjustable reactivation delay
Configurable reactivation Block
Also for single phase connections
Relay output, 2 changeovers
35 mm overall width
In accordance with IEC 255, VDE 0435 Section 303
Green LED indicates for closed contact
Optionally for 3p3w systems
Manual reset is possible with external circuit