Technical Document
Specifications
Brand
ElectrothermProduct Type
RTD Sensor
Sensor Type
PT100
Probe Length
50mm
Probe Diameter
3 mm
Minimum Temperature Sensed
-50°C
Maximum Temperature Sensed
200°C
Termination Type
Cable
Cable Length
2.5m
Hazardous Area Certification
No
Accuracy
F0.3
Country of Origin
Germany
Product details
Type K3 - high-temperature cable sensor, PT100
Resistance thermometer without fastening element
Temperature measurement and monitoring on diverse application sites
Temperature range: -50 °C → +200 °C or +400 °C
Design with cable connection sleeve
Two or three-conductor circuit
Accuracy class B
2.5 m connection lead
Protective tube Ø 3 x 50 mm with connection sleeves with Ø of 6 x 30 mm made from stainless steel
400 °C version with cable sheathing reinforced with fibre glass
Standards
Base values and limit deviations according to DIN EN 60751
Stock information temporarily unavailable.
AED 429.50
AED 429.50 Each (ex VAT)
AED 450.97
AED 450.97 Each (inc. VAT)
1
AED 429.50
AED 429.50 Each (ex VAT)
AED 450.97
AED 450.97 Each (inc. VAT)
Stock information temporarily unavailable.
1
| Quantity | Unit price |
|---|---|
| 1 - 4 | AED 429.50 |
| 5+ | AED 411.90 |
Technical Document
Specifications
Brand
ElectrothermProduct Type
RTD Sensor
Sensor Type
PT100
Probe Length
50mm
Probe Diameter
3 mm
Minimum Temperature Sensed
-50°C
Maximum Temperature Sensed
200°C
Termination Type
Cable
Cable Length
2.5m
Hazardous Area Certification
No
Accuracy
F0.3
Country of Origin
Germany
Product details
Type K3 - high-temperature cable sensor, PT100
Resistance thermometer without fastening element
Temperature measurement and monitoring on diverse application sites
Temperature range: -50 °C → +200 °C or +400 °C
Design with cable connection sleeve
Two or three-conductor circuit
Accuracy class B
2.5 m connection lead
Protective tube Ø 3 x 50 mm with connection sleeves with Ø of 6 x 30 mm made from stainless steel
400 °C version with cable sheathing reinforced with fibre glass
Standards
Base values and limit deviations according to DIN EN 60751