Technical Documents
Specifications
Brand
EYCProduct Type
Signal Conditioner
Output Signal Type
Current/Voltage
Supply Voltage
253, 85V ac
Hazardous Area Certification
No
Mount Type
DIN Rail
Maximum Operating Temperature
60°C
Minimum Operating Temperature
-10°C
Terminal Type
Screw
IP Rating
IP20
Standards/Approvals
EN 61000-3-2:2014, IEC 61000-4-6:2013, IEC 61000-4-2:2008, Immunity EN 61326-1:2013, IEC 61000-4-4:2012, IEC 61000-4-8:2009, EN 61000-3-3:2013, CE Certification, IEC 61000-4-3:2006+A1:2007+A2:2010, CISPR11:2009+A1:2010 Group 1 Class B, IEC 61000-4-5:2014, IEC 61000-4-11:2004, Emission EN 61326-1:2013
Series
DPT02
Country of Origin
Taiwan, Province Of China
Product Details
EYC-Tech DPT02 series digital universal input signal converters measure a wide range of input types and convert these into an analogue output. The DPT02 features a 3-digit readout display and simple keypad for programming the signal output and scale.
Stock information temporarily unavailable.
AED 861.30
AED 861.30 Each (ex VAT)
AED 904.36
AED 904.36 Each (inc. VAT)
1
AED 861.30
AED 861.30 Each (ex VAT)
AED 904.36
AED 904.36 Each (inc. VAT)
Stock information temporarily unavailable.
1
Technical Documents
Specifications
Brand
EYCProduct Type
Signal Conditioner
Output Signal Type
Current/Voltage
Supply Voltage
253, 85V ac
Hazardous Area Certification
No
Mount Type
DIN Rail
Maximum Operating Temperature
60°C
Minimum Operating Temperature
-10°C
Terminal Type
Screw
IP Rating
IP20
Standards/Approvals
EN 61000-3-2:2014, IEC 61000-4-6:2013, IEC 61000-4-2:2008, Immunity EN 61326-1:2013, IEC 61000-4-4:2012, IEC 61000-4-8:2009, EN 61000-3-3:2013, CE Certification, IEC 61000-4-3:2006+A1:2007+A2:2010, CISPR11:2009+A1:2010 Group 1 Class B, IEC 61000-4-5:2014, IEC 61000-4-11:2004, Emission EN 61326-1:2013
Series
DPT02
Country of Origin
Taiwan, Province Of China
Product Details
EYC-Tech DPT02 series digital universal input signal converters measure a wide range of input types and convert these into an analogue output. The DPT02 features a 3-digit readout display and simple keypad for programming the signal output and scale.