Technical Document
Specifications
Brand
HOBUTProduct Type
Current Transformer
Series
CTSCM
Terminal Type
Flying Lead
Primary Current
500A
Minimum Operating Temperature
-15°C
Maximum Operating Temperature
50°C
Length
1m
Standards/Approvals
UL 94V-0
Maximum Operating Frequency
400Hz
Mount Type
Cable
Minimum Operating Frequency
50Hz
Bore Size
35mm
Country of Origin
United Kingdom
Product details
mV Split Core Current Transformers
A range of mV split core current transformers are designed to fit into confined spaces while the primary conductor is still live. The current transformers are made in a compact design with a mechanical hinge for multiples opening and closing action. For connection into existing networks, they are often for use with multi function meters that have 0.333 V input.
High sensitivity
Class 1 accuracy
Construction- ferrite core material
Case nylon UL flame retardant rating 94V-0
Linearity with minimum phase shift
0.333 V ac secondary output at rated current
Mechanical hinge
Input frequency 50 Hz to 400 Hz
Maximum primary voltage 720 V ac
1 m long flying lead twisted pair (22 AWG)
Current Transformers
Stock information temporarily unavailable.
AED 220.79
AED 220.79 Each (ex VAT)
AED 231.83
AED 231.83 Each (inc. VAT)
1
AED 220.79
AED 220.79 Each (ex VAT)
AED 231.83
AED 231.83 Each (inc. VAT)
Stock information temporarily unavailable.
1
| Quantity | Unit price |
|---|---|
| 1 - 4 | AED 220.79 |
| 5 - 9 | AED 214.00 |
| 10+ | AED 207.04 |
Technical Document
Specifications
Brand
HOBUTProduct Type
Current Transformer
Series
CTSCM
Terminal Type
Flying Lead
Primary Current
500A
Minimum Operating Temperature
-15°C
Maximum Operating Temperature
50°C
Length
1m
Standards/Approvals
UL 94V-0
Maximum Operating Frequency
400Hz
Mount Type
Cable
Minimum Operating Frequency
50Hz
Bore Size
35mm
Country of Origin
United Kingdom
Product details
mV Split Core Current Transformers
A range of mV split core current transformers are designed to fit into confined spaces while the primary conductor is still live. The current transformers are made in a compact design with a mechanical hinge for multiples opening and closing action. For connection into existing networks, they are often for use with multi function meters that have 0.333 V input.
High sensitivity
Class 1 accuracy
Construction- ferrite core material
Case nylon UL flame retardant rating 94V-0
Linearity with minimum phase shift
0.333 V ac secondary output at rated current
Mechanical hinge
Input frequency 50 Hz to 400 Hz
Maximum primary voltage 720 V ac
1 m long flying lead twisted pair (22 AWG)