Technical Document
Specifications
Brand
HoneywellActuator Type
Plunger
Pole and Throw Configuration
SPDT
Normal State Configuration
NO/NC
Maximum Current
20A
Housing Material
Die Cast Aluminium
Maximum AC Voltage
480V
Maximum DC Voltage
250V
Connection Type
1/2 in NPT
Series
BAF
Action Type
Snap Action
Length
101.6mm
Depth
33mm
Width
54.8mm
Maximum Operating Temperature
+71°C
Minimum Operating Temperature
-32°C
Mounting Orientation
Vertical
Country of Origin
United States
Product details
BAF Medium Duty Limit Switches
The BAF limit switch series from Honeywell is designed for use within a medium duty environment. The elastomer boot on sealed actuator verions protects the actuating mechanism and the internal basic switch from contaminants. There is a seal gasket between the cover plate and the enclosures on all versions. The cover plate is removed for ease of wiring and switch replacement without demounting the switch. The actuator position is designated "right" or "left," when looking at the nameplate.
Cast aluminium housing
Cover seal, captive cover screws
Momentary or maintained contact
Stock information temporarily unavailable.
Please check again later.
AED 1,202.90
AED 1,202.90 Each (ex VAT)
AED 1,263.04
AED 1,263.04 Each (inc. VAT)
1
AED 1,202.90
AED 1,202.90 Each (ex VAT)
AED 1,263.04
AED 1,263.04 Each (inc. VAT)
1
Buy in bulk
quantity | Unit price |
---|---|
1 - 4 | AED 1,202.90 |
5 - 9 | AED 1,154.75 |
10+ | AED 1,106.75 |
Technical Document
Specifications
Brand
HoneywellActuator Type
Plunger
Pole and Throw Configuration
SPDT
Normal State Configuration
NO/NC
Maximum Current
20A
Housing Material
Die Cast Aluminium
Maximum AC Voltage
480V
Maximum DC Voltage
250V
Connection Type
1/2 in NPT
Series
BAF
Action Type
Snap Action
Length
101.6mm
Depth
33mm
Width
54.8mm
Maximum Operating Temperature
+71°C
Minimum Operating Temperature
-32°C
Mounting Orientation
Vertical
Country of Origin
United States
Product details
BAF Medium Duty Limit Switches
The BAF limit switch series from Honeywell is designed for use within a medium duty environment. The elastomer boot on sealed actuator verions protects the actuating mechanism and the internal basic switch from contaminants. There is a seal gasket between the cover plate and the enclosures on all versions. The cover plate is removed for ease of wiring and switch replacement without demounting the switch. The actuator position is designated "right" or "left," when looking at the nameplate.
Cast aluminium housing
Cover seal, captive cover screws
Momentary or maintained contact