Technical Document
Specifications
Brand
HoneywellMaximum Overload Pressure
30psi
Product Type
Absolute Pressure Sensor
Sensor Type
Absolute Pressure Sensor
Mount Type
Through Hole
Package Type
PDIP
Pin Count
8
Minimum Supply Voltage
3.3V
Maximum Operating Pressure
15 psi
Maximum Supply Voltage
5.25V
Accuracy
±0.25 %
Port Type
Single Axial Barbed
Maximum Operating Temperature
85°C
Width
13.5 mm
Maximum Output Voltage
5.25V
Height
13.75mm
Length
10mm
Standards/Approvals
No
Series
SSC
Minimum Operating Pressure
0psi
Minimum Output Voltage
4.75V
Minimum Operating Temperature
-40°C
Automotive Standard
No
Country of Origin
China
Product details
Honeywell TruStability® SSC Series Pressure Sensors
The TruStability® Standard Accuracy Silicon Ceramic (SSC) series are piezo-resistive silicon pressure sensors. They have have been designed to offer digital outputs for reading pressure which will be over a specified pressure and temperature range. The devices are fully calibrated during manufacture via an on-board ASIC and are compensated for sensing offset, sensitivity, temperature effects and non-linearity. Calibrated output values for pressure are updated at approximately 2 kHz. The units have been calibrated to operate within a temperature range of -20 to +85 °C and operate from a single power supply of either 3.3 or 5.0 V DC.
The range includes units for measuring differential and gauge pressure, differential versions allow application of pressure to either side of the sensing diaphragm whilst gauge versions are referenced to atmospheric pressure and provide an output proportional to pressure variations from atmosphere.
Potential applications include:
Medical - Ventilators, anaesthesia machines, spirometers, nebulizers, hospital room air pressure
Industrial - VAV (Variable Air Volume) control, static duct pressure, clogged HVAC (Heating, Ventilation, and Air Conditioning) filter detection, HVAC transmitters, indoor air quality
Features:
Combines high sensitivity with high overpressure and burst pressure
Long-term stability
Minimizes system calibration needs
Eliminates individually testing and calibrating every sensor
Extremely tight accuracy of ±0.25% FSS BFSL (Full Scale Span Best Fit Straight Line)
Pressure Sensors, Honeywell
Stock information temporarily unavailable.
AED 197.52
AED 197.52 Each (ex VAT)
AED 207.40
AED 207.40 Each (inc. VAT)
1
AED 197.52
AED 197.52 Each (ex VAT)
AED 207.40
AED 207.40 Each (inc. VAT)
Stock information temporarily unavailable.
1
Technical Document
Specifications
Brand
HoneywellMaximum Overload Pressure
30psi
Product Type
Absolute Pressure Sensor
Sensor Type
Absolute Pressure Sensor
Mount Type
Through Hole
Package Type
PDIP
Pin Count
8
Minimum Supply Voltage
3.3V
Maximum Operating Pressure
15 psi
Maximum Supply Voltage
5.25V
Accuracy
±0.25 %
Port Type
Single Axial Barbed
Maximum Operating Temperature
85°C
Width
13.5 mm
Maximum Output Voltage
5.25V
Height
13.75mm
Length
10mm
Standards/Approvals
No
Series
SSC
Minimum Operating Pressure
0psi
Minimum Output Voltage
4.75V
Minimum Operating Temperature
-40°C
Automotive Standard
No
Country of Origin
China
Product details
Honeywell TruStability® SSC Series Pressure Sensors
The TruStability® Standard Accuracy Silicon Ceramic (SSC) series are piezo-resistive silicon pressure sensors. They have have been designed to offer digital outputs for reading pressure which will be over a specified pressure and temperature range. The devices are fully calibrated during manufacture via an on-board ASIC and are compensated for sensing offset, sensitivity, temperature effects and non-linearity. Calibrated output values for pressure are updated at approximately 2 kHz. The units have been calibrated to operate within a temperature range of -20 to +85 °C and operate from a single power supply of either 3.3 or 5.0 V DC.
The range includes units for measuring differential and gauge pressure, differential versions allow application of pressure to either side of the sensing diaphragm whilst gauge versions are referenced to atmospheric pressure and provide an output proportional to pressure variations from atmosphere.
Potential applications include:
Medical - Ventilators, anaesthesia machines, spirometers, nebulizers, hospital room air pressure
Industrial - VAV (Variable Air Volume) control, static duct pressure, clogged HVAC (Heating, Ventilation, and Air Conditioning) filter detection, HVAC transmitters, indoor air quality
Features:
Combines high sensitivity with high overpressure and burst pressure
Long-term stability
Minimizes system calibration needs
Eliminates individually testing and calibrating every sensor
Extremely tight accuracy of ±0.25% FSS BFSL (Full Scale Span Best Fit Straight Line)