Technical Document
Specifications
Brand
Phoenix ContactModule Type
Power Terminal Block
Input Signal Type
Voltage
Output Signal Type
Voltage
Input Range
0 → 30V
Output Range
19.2 → 29.2V dc
Supply Voltage
0 → 30V dc
Mounting Type
DIN Rail Mount
Operating Temperature Range
-20 → +65°C
Series
MINI MCR-2-UNI-UI-2UI
Standards Met
CE
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+65°C
Country of Origin
Germany
Product details
MCR Power Terminal Block
The MINI MCR-SL-PTB-FM(-SP) power terminal is used to supply the supply voltage to the DIN rail connector.
Two separate voltage inputs allow for redundant voltage supply, which is decoupled from diodes, up to a maximum current of 2 A.
The MINI MCR-SL-PTB-FM(-SP) power terminal provides the following functions:
– Monitoring in conjunction with the MINI MCR-SL-FMRC-NC fault monitoring module (RS stock-no.: 785-7799) or MINI MCR-SL-FM-RC-SP-NC (RS stock-no.: 785-7793)
– Flexible redundant supply from one or both module sides
Approval for Ex-zone 2 (nA)
Screw or spring-cage connection are available:
Screw connection (RS stock-no. 785-7787)
Spring-cage connection(RS stock-no. 785-7796)
DIN rail mounting
Stock information temporarily unavailable.
Please check again later.
AED 302.70
AED 302.70 Each (ex VAT)
AED 317.84
AED 317.84 Each (inc. VAT)
1
AED 302.70
AED 302.70 Each (ex VAT)
AED 317.84
AED 317.84 Each (inc. VAT)
1
Technical Document
Specifications
Brand
Phoenix ContactModule Type
Power Terminal Block
Input Signal Type
Voltage
Output Signal Type
Voltage
Input Range
0 → 30V
Output Range
19.2 → 29.2V dc
Supply Voltage
0 → 30V dc
Mounting Type
DIN Rail Mount
Operating Temperature Range
-20 → +65°C
Series
MINI MCR-2-UNI-UI-2UI
Standards Met
CE
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+65°C
Country of Origin
Germany
Product details
MCR Power Terminal Block
The MINI MCR-SL-PTB-FM(-SP) power terminal is used to supply the supply voltage to the DIN rail connector.
Two separate voltage inputs allow for redundant voltage supply, which is decoupled from diodes, up to a maximum current of 2 A.
The MINI MCR-SL-PTB-FM(-SP) power terminal provides the following functions:
– Monitoring in conjunction with the MINI MCR-SL-FMRC-NC fault monitoring module (RS stock-no.: 785-7799) or MINI MCR-SL-FM-RC-SP-NC (RS stock-no.: 785-7793)
– Flexible redundant supply from one or both module sides
Approval for Ex-zone 2 (nA)
Screw or spring-cage connection are available:
Screw connection (RS stock-no. 785-7787)
Spring-cage connection(RS stock-no. 785-7796)
DIN rail mounting