Promotional Code

Use promotional code RSUAE5 and get extra 5% off on the price of all products | Payment Options: Debit or Credit Card, Wire Transfer, Cash or Cheque

Phoenix Contact MINI MCR Series Signal Conditioner, RTD, Thermocouple Input, Transistor Output, 24V dc Supply, ATEX

RS Stock No.: 134-8689Brand: Phoenix ContactManufacturers Part No.: 2906877Distrelec Article No.: 30103302
brand-logo
View all in Signal Conditioners

Technical Document

Specifications

Module Type

Limit Value Switch

Input Signal Type

RTD, Thermocouple

Output Signal Type

Transistor

Input Range

0 → 4000 Ω

Output Range

70 mA, 100mA

Supply Voltage

24V dc

Hazardous Area Certification

ATEX

Mounting Type

DIN Rail Mount

Operating Temperature Range

-40 → +70°C

Series

MINI MCR

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+70°C

Termination

Push-In

Product details

MINI MCR - Limit Value Switches

MINI MCR series limit value switches, with adjustable hysteresis and delay time and spring-cage connection.

Power supply possible via the foot element (T-connector)
Status and error indication via two diagnostic LEDs
PDT relay at output
3-way isolation
Limit value can be freely adjusted via potentioemeter on the front
Highly-compact threshold value switch for switching analog limit values

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

AED 963.45

Each (ex VAT)

AED 1,011.62

Each (inc. VAT)

Phoenix Contact MINI MCR Series Signal Conditioner, RTD, Thermocouple Input, Transistor Output, 24V dc Supply, ATEX

AED 963.45

Each (ex VAT)

AED 1,011.62

Each (inc. VAT)

Phoenix Contact MINI MCR Series Signal Conditioner, RTD, Thermocouple Input, Transistor Output, 24V dc Supply, ATEX
Stock information temporarily unavailable.

Technical Document

Specifications

Module Type

Limit Value Switch

Input Signal Type

RTD, Thermocouple

Output Signal Type

Transistor

Input Range

0 → 4000 Ω

Output Range

70 mA, 100mA

Supply Voltage

24V dc

Hazardous Area Certification

ATEX

Mounting Type

DIN Rail Mount

Operating Temperature Range

-40 → +70°C

Series

MINI MCR

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+70°C

Termination

Push-In

Product details

MINI MCR - Limit Value Switches

MINI MCR series limit value switches, with adjustable hysteresis and delay time and spring-cage connection.

Power supply possible via the foot element (T-connector)
Status and error indication via two diagnostic LEDs
PDT relay at output
3-way isolation
Limit value can be freely adjusted via potentioemeter on the front
Highly-compact threshold value switch for switching analog limit values