Phoenix Contact PSR-TRISAFE PSR-SPP- 24DC/TS/S Series Safety Controller, 20 Safety Inputs, 6 Safety Outputs, 24 V dc

RS Stock No.: 666-7126Brand: Phoenix ContactManufacturers Part No.: 2986232
brand-logo

Technical Document

Specifications

Range

PSR-TRISAFE

Series

PSR-SPP- 24DC/TS/S

Number of Safety Inputs

20

Number of Safety Outputs

6

Safety Category

4

SIL

SIL 3

Supply Voltage

24 V dc

Contact Current Rating

2 A

Contact Voltage Rating

24 V dc

IP Rating

IP20, IP54

Dimensions

114.5 x 67.5 x 112 mm

Depth

112mm

Length

114.5mm

Width

67.5mm

Country of Origin

Germany

Product details

PSR-TRISAFE-S Safety Controller

The PSR-TRISAFE-S is a standalone safety controller with 20 safe inputs, four safe outputs and two safe ground-switching outputs. If additional safe outputs or safe relay outputs are needed, standard safety relay expansion modules can be hard-wired to the safe outputs of the PSR-TRISAFE-S module. System designers should consider adding a safety expansion relay for one of two reasons: (a) the PSR-TRISAFE-S module does not have enough safe outputs; (b) a safe relay circuit is needed to switch a voltage other than 24 Vdc. The PSR-TRISAFE-S module is a 24 V solid-state device.

Intuitive three step software
Manipulation proof: Password protect against unathorised changes in the safety logic of the hardware and software: Protect against unwanted changes in the safety logic with the front of device "CONFIRM" button
All commonly used safety functions can be implemented easily and flexibly: E-stop and guard door monitoring, non-contact switches, safety sensors, laser scanners, optical devices (with or without muting) as well as safe mode selection, enabling switches, two hand control devices
2 clock outputs, 4 alarm outputs and ground switching output to increase safety of monitoring circuit

Approvals

TUV FS, UL, cUL

Standards

EN954-1 to Category 4, ISO 13849-1 to PLe, IEC 62061 to SILCL 3 for machine and system engineering
SIL3 to IEC 61508 for the Process Industry

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

AED 3,584.45

Each (ex VAT)

AED 3,763.67

Each (inc VAT)

Phoenix Contact PSR-TRISAFE PSR-SPP- 24DC/TS/S Series Safety Controller, 20 Safety Inputs, 6 Safety Outputs, 24 V dc

AED 3,584.45

Each (ex VAT)

AED 3,763.67

Each (inc VAT)

Phoenix Contact PSR-TRISAFE PSR-SPP- 24DC/TS/S Series Safety Controller, 20 Safety Inputs, 6 Safety Outputs, 24 V dc
Stock information temporarily unavailable.

Technical Document

Specifications

Range

PSR-TRISAFE

Series

PSR-SPP- 24DC/TS/S

Number of Safety Inputs

20

Number of Safety Outputs

6

Safety Category

4

SIL

SIL 3

Supply Voltage

24 V dc

Contact Current Rating

2 A

Contact Voltage Rating

24 V dc

IP Rating

IP20, IP54

Dimensions

114.5 x 67.5 x 112 mm

Depth

112mm

Length

114.5mm

Width

67.5mm

Country of Origin

Germany

Product details

PSR-TRISAFE-S Safety Controller

The PSR-TRISAFE-S is a standalone safety controller with 20 safe inputs, four safe outputs and two safe ground-switching outputs. If additional safe outputs or safe relay outputs are needed, standard safety relay expansion modules can be hard-wired to the safe outputs of the PSR-TRISAFE-S module. System designers should consider adding a safety expansion relay for one of two reasons: (a) the PSR-TRISAFE-S module does not have enough safe outputs; (b) a safe relay circuit is needed to switch a voltage other than 24 Vdc. The PSR-TRISAFE-S module is a 24 V solid-state device.

Intuitive three step software
Manipulation proof: Password protect against unathorised changes in the safety logic of the hardware and software: Protect against unwanted changes in the safety logic with the front of device "CONFIRM" button
All commonly used safety functions can be implemented easily and flexibly: E-stop and guard door monitoring, non-contact switches, safety sensors, laser scanners, optical devices (with or without muting) as well as safe mode selection, enabling switches, two hand control devices
2 clock outputs, 4 alarm outputs and ground switching output to increase safety of monitoring circuit

Approvals

TUV FS, UL, cUL

Standards

EN954-1 to Category 4, ISO 13849-1 to PLe, IEC 62061 to SILCL 3 for machine and system engineering
SIL3 to IEC 61508 for the Process Industry