Technical Document
Specifications
Brand
P.M.AModule Type
Universal Signal Converter
Input Signal Type
Universal
Output Signal Type
Universal
Input Range
0 → 20 mA, -10/0 → 10 V, -5 → 5 V, Potentiometer 0 → 4500 Ω, Thermocouples Pt100 / Pt1000 / KTY11-6
Output Range
14 bit, 0 → 10 V, 0 → 20mA
Supply Voltage
90 → 260V ac
Mounting Type
DIN Rail Mount
Operating Temperature Range
-20 → +60°C
Series
CI45
Standards Met
cUL, UL
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+60°C
Termination
Screw/Spring
Country of Origin
United Kingdom
Product details
PMA UNIFLEX CI 45 Temperature Transmitter
UNIFLEX CI 45 transmitters are designed to give precise and cost-effective signal detection and processing. Every CI 45 has at least one universal input, one universal output and a relay.
Optionally, the transmitter can be fitted with an additional relay, with a second universal input and counter or frequency input. Optionally, the voltage output can also be used as frequency output. Galvanic isolation is provided between inputs and outputs as well as from the supply voltage and the communication interfaces.
Compact design
Display & operating functions
Communication features
High resolution
Fast cycle times
Two universal inputs & universal output
Two relay outputs
Counter/ frequency input, frequency output
Customer-specific linearization
Measurement value correction
Min/max indicator (slave pointer)
PMA Temperature Transmitters
Stock information temporarily unavailable.
Please check again later.
AED 1,561.35
Each (ex VAT)
AED 1,639.42
Each (inc. VAT)
1
AED 1,561.35
Each (ex VAT)
AED 1,639.42
Each (inc. VAT)
1
Technical Document
Specifications
Brand
P.M.AModule Type
Universal Signal Converter
Input Signal Type
Universal
Output Signal Type
Universal
Input Range
0 → 20 mA, -10/0 → 10 V, -5 → 5 V, Potentiometer 0 → 4500 Ω, Thermocouples Pt100 / Pt1000 / KTY11-6
Output Range
14 bit, 0 → 10 V, 0 → 20mA
Supply Voltage
90 → 260V ac
Mounting Type
DIN Rail Mount
Operating Temperature Range
-20 → +60°C
Series
CI45
Standards Met
cUL, UL
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+60°C
Termination
Screw/Spring
Country of Origin
United Kingdom
Product details
PMA UNIFLEX CI 45 Temperature Transmitter
UNIFLEX CI 45 transmitters are designed to give precise and cost-effective signal detection and processing. Every CI 45 has at least one universal input, one universal output and a relay.
Optionally, the transmitter can be fitted with an additional relay, with a second universal input and counter or frequency input. Optionally, the voltage output can also be used as frequency output. Galvanic isolation is provided between inputs and outputs as well as from the supply voltage and the communication interfaces.
Compact design
Display & operating functions
Communication features
High resolution
Fast cycle times
Two universal inputs & universal output
Two relay outputs
Counter/ frequency input, frequency output
Customer-specific linearization
Measurement value correction
Min/max indicator (slave pointer)