Technical Document
Specifications
Connection
1/2 in BSP Male
Maximum Set Pressure
7bar
Maximum Temperature
+95°C
For Use With
Hot Water
Connection Gender
Male
Thread Size
1/4in
Thread Standard or Connection Type
BSP
Country of Origin
United States
Product details
Full Cartridge Pressure and Temperature Relief Valve
All Reliance pressure vessels are supplied with a replaceable membrane, which separates the water and air, to prevent contamination of the water system, corrosion of the pressure vessel or pressure loss in the water system.
Typically pressure vessels are used in pumped systems. When the pump starts, the pressure inside the vessel begins to increase. Once the vessel is full and the pump has reached its high pressure setting it will switch off. When water is then drawn off from the system the air pressure surrounding the membrane will force the water out of the pressure vessel and into the system. Once the membrane is fully deflated and the system has reached its minimum pressure, the pump will start on its low pressure setting and will begin the cycle again.
The purpose of this system is to prevent constant cycling of the pump and continuous running when the system is being used
Protect against temperature rising above 95゚C
Prevent over pressurisation
Twist toop cartridge design for easy servicing
Range of different pressure settings and different probe lenghts
Approvals
WRAS
Stock information temporarily unavailable.
Please check again later.
AED 347.35
AED 347.35 Each (ex VAT)
AED 364.72
AED 364.72 Each (inc. VAT)
1
AED 347.35
AED 347.35 Each (ex VAT)
AED 364.72
AED 364.72 Each (inc. VAT)
1
Buy in bulk
quantity | Unit price |
---|---|
1 - 4 | AED 347.35 |
5 - 9 | AED 340.20 |
10+ | AED 334.25 |
Technical Document
Specifications
Connection
1/2 in BSP Male
Maximum Set Pressure
7bar
Maximum Temperature
+95°C
For Use With
Hot Water
Connection Gender
Male
Thread Size
1/4in
Thread Standard or Connection Type
BSP
Country of Origin
United States
Product details
Full Cartridge Pressure and Temperature Relief Valve
All Reliance pressure vessels are supplied with a replaceable membrane, which separates the water and air, to prevent contamination of the water system, corrosion of the pressure vessel or pressure loss in the water system.
Typically pressure vessels are used in pumped systems. When the pump starts, the pressure inside the vessel begins to increase. Once the vessel is full and the pump has reached its high pressure setting it will switch off. When water is then drawn off from the system the air pressure surrounding the membrane will force the water out of the pressure vessel and into the system. Once the membrane is fully deflated and the system has reached its minimum pressure, the pump will start on its low pressure setting and will begin the cycle again.
The purpose of this system is to prevent constant cycling of the pump and continuous running when the system is being used
Protect against temperature rising above 95゚C
Prevent over pressurisation
Twist toop cartridge design for easy servicing
Range of different pressure settings and different probe lenghts
Approvals
WRAS