Supply Voltage

115 → 230V ac

Number of Channels

2

Safety Contacts

2

Function

Two Hand Control

Auxiliary Contacts

1

Range

Preventa

Safety Category ISO 13849-1

1

Safety Category (ISO 13849-1)

1

PL ISO 13849-1

c

PL (ISO 13849-1)

c

SIL IEC 61508

1

SIL (IEC 61508)

1

Terminal Type

Screw

Width

114mm

Series

XPS BA

Depth

99mm

Performance Level

c

Length

22.5mm

Country of Origin

Germany

Product details

Schneider Electric Preventa XPS Series Safety Relay for a Two Hand Control Station.

Schneider Electric Preventa XPS BAE safety relay provides you with the ultimate solution for safety relay electrical monitoring function. Designed to be used with Two-hand control stations ensuring your protection from and injuries to your hands keeping your hands away from the movement area complying with EN 574/ISO 13851.

Two Hand Control Station Operation.

  • Two hand control stations must be designed and installed so that they cannot be activated involuntarily or easily rendered inoperative. Depending on the application, the requirements of type C standards specific to the machinery involved must be met.

  • To initiate a dangerous movement, both operators (two-hand control pushbuttons) must be activated within an interval y 0.5 s (synchronous activation). If one of the two pushbuttons is released during a dangerous operation, the control sequence is cancelled.

  • Resumption of the dangerous operation is possible only if both pushbuttons are returned to their initial position and reactivated within the required time interval.

  • The safety distance between the control units and the hazardous zone must be sufficient to ensure that when only one operator is released, the hazardous zone cannot be reached before the dangerous movement has been completed or stopped.

  • Maximum achievable safety level b PL c/Category 1 conforming to EN/ISO 13849-1 b SILCL1 conforming to EN/IEC 62061 Product certifications b UL b CSA b TÜV.

Features.

  • Monitoring two-hand control station type IIIA

  • Captive screw clamp terminals

  • 2 LEDs for signalling

  • 35mm symmetrical DIN rail mounted

Standards

EN/IEC 60204-1, EN/IEC 60947-5-1, EN/ISO 13849-1, EN 62061, EN 574 type III A, EN 60947-01.

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

AED 468.80

Each (ex VAT)

AED 492.24

Each (inc. VAT)

Schneider Electric Dual-Channel Two Hand Control Safety Relay, 115 → 230V ac, 2 Safety Contacts

AED 468.80

Each (ex VAT)

AED 492.24

Each (inc. VAT)

Schneider Electric Dual-Channel Two Hand Control Safety Relay, 115 → 230V ac, 2 Safety Contacts
Stock information temporarily unavailable.

Technical Document

Specifications

Supply Voltage

115 → 230V ac

Number of Channels

2

Safety Contacts

2

Function

Two Hand Control

Auxiliary Contacts

1

Range

Preventa

Safety Category ISO 13849-1

1

Safety Category (ISO 13849-1)

1

PL ISO 13849-1

c

PL (ISO 13849-1)

c

SIL IEC 61508

1

SIL (IEC 61508)

1

Terminal Type

Screw

Width

114mm

Series

XPS BA

Depth

99mm

Performance Level

c

Length

22.5mm

Country of Origin

Germany

Product details

Schneider Electric Preventa XPS Series Safety Relay for a Two Hand Control Station.

Schneider Electric Preventa XPS BAE safety relay provides you with the ultimate solution for safety relay electrical monitoring function. Designed to be used with Two-hand control stations ensuring your protection from and injuries to your hands keeping your hands away from the movement area complying with EN 574/ISO 13851.

Two Hand Control Station Operation.

  • Two hand control stations must be designed and installed so that they cannot be activated involuntarily or easily rendered inoperative. Depending on the application, the requirements of type C standards specific to the machinery involved must be met.

  • To initiate a dangerous movement, both operators (two-hand control pushbuttons) must be activated within an interval y 0.5 s (synchronous activation). If one of the two pushbuttons is released during a dangerous operation, the control sequence is cancelled.

  • Resumption of the dangerous operation is possible only if both pushbuttons are returned to their initial position and reactivated within the required time interval.

  • The safety distance between the control units and the hazardous zone must be sufficient to ensure that when only one operator is released, the hazardous zone cannot be reached before the dangerous movement has been completed or stopped.

  • Maximum achievable safety level b PL c/Category 1 conforming to EN/ISO 13849-1 b SILCL1 conforming to EN/IEC 62061 Product certifications b UL b CSA b TÜV.

Features.

  • Monitoring two-hand control station type IIIA

  • Captive screw clamp terminals

  • 2 LEDs for signalling

  • 35mm symmetrical DIN rail mounted

Standards

EN/IEC 60204-1, EN/IEC 60947-5-1, EN/ISO 13849-1, EN 62061, EN 574 type III A, EN 60947-01.