Technical Documents
Specifications
Brand
TDK-LambdaProduct Type
Switching Power Supply
Maximum Output Voltage
48V dc
Number of Outputs
2
Mount Type
Panel
Power
400W
Minimum Operating Temperature
-20°C
SMPS Output Current
5.21A
Maximum Operating Temperature
70°C
Depth
198mm
Weight
440g
Standards/Approvals
IEC 61000-4-8 (lv 4), IEC/UL/CSA/EN 62368-1, IEC 61000-4-4 (lv 3), IEC 61000-4-5 (lv 3,4), IEC 61000-4-6 (lv 3), CE, EN 55022-B, FCC-B, IEC 61000-4-11, IEC 61000-4-2 (lv 2,3), IEC 61000-4-3 (lv3)
Width
128mm
Length
198mm
Efficiency
90%
Maximum Input Voltage
264V ac
Series
CUS400M
Output Current
5.21A
Hazardous Area Certification
No
Minimum Input Voltage
85V ac
Country of Origin
United Kingdom
Product Details
The TDK-Lambda compact CUS400M is packaged in the industry standard 3x5 footprint. The series can deliver 400W with forced air or 250W when convection cooled with a 400W peak power for extended periods of time (minutes). Cooling is also assisted via conduction through the base into the equipment chassis. With Medical & ITE certifications, the units can be used in both Class I & Class II (no ground wire) applications, and meets Class B Conducted and Radiated EMI. Options include a standby voltage, signalling and multiple case options.
Stock information temporarily unavailable.
AED 1,128.85
AED 1,128.85 Each (ex VAT)
AED 1,185.29
AED 1,185.29 Each (inc. VAT)
1
AED 1,128.85
AED 1,128.85 Each (ex VAT)
AED 1,185.29
AED 1,185.29 Each (inc. VAT)
Stock information temporarily unavailable.
1
| Quantity | Unit price |
|---|---|
| 1 - 4 | AED 1,128.85 |
| 5 - 9 | AED 1,094.98 |
| 10 - 24 | AED 1,065.18 |
| 25 - 49 | AED 1,047.53 |
| 50+ | AED 1,028.97 |
Technical Documents
Specifications
Brand
TDK-LambdaProduct Type
Switching Power Supply
Maximum Output Voltage
48V dc
Number of Outputs
2
Mount Type
Panel
Power
400W
Minimum Operating Temperature
-20°C
SMPS Output Current
5.21A
Maximum Operating Temperature
70°C
Depth
198mm
Weight
440g
Standards/Approvals
IEC 61000-4-8 (lv 4), IEC/UL/CSA/EN 62368-1, IEC 61000-4-4 (lv 3), IEC 61000-4-5 (lv 3,4), IEC 61000-4-6 (lv 3), CE, EN 55022-B, FCC-B, IEC 61000-4-11, IEC 61000-4-2 (lv 2,3), IEC 61000-4-3 (lv3)
Width
128mm
Length
198mm
Efficiency
90%
Maximum Input Voltage
264V ac
Series
CUS400M
Output Current
5.21A
Hazardous Area Certification
No
Minimum Input Voltage
85V ac
Country of Origin
United Kingdom
Product Details
The TDK-Lambda compact CUS400M is packaged in the industry standard 3x5 footprint. The series can deliver 400W with forced air or 250W when convection cooled with a 400W peak power for extended periods of time (minutes). Cooling is also assisted via conduction through the base into the equipment chassis. With Medical & ITE certifications, the units can be used in both Class I & Class II (no ground wire) applications, and meets Class B Conducted and Radiated EMI. Options include a standby voltage, signalling and multiple case options.