Telemecanique Sensors XY2-CE Rope Pull Switch, 2NO/2NC

RS Stock No.: 814-8129Brand: Telemecanique SensorsManufacturers Part No.: XY2CE2A296H7
brand-logo
View all in Rope Pull Switches

Technical Document

Specifications

Normal State Configuration

2NO/2NC

Series

XY2-CE

Range

Preventa

Maximum AC Voltage

300V

Maximum Current

10A

Country of Origin

Morocco

Product details

Telemecanique XY2CE & XY2CB Emergency Stop Rope Pull Switches

These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the trip wire breaking.

Switches incorporate positive opening operation contacts, the tripping of the switch being made with positive action
The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling
Incorporates a reset button, which re-closes the safety contact(s), restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch
Recommended distance between cable supports is 15m (for model XY2-CB30 a distance of 20m is recommended)
The XY2 CE1A296 comes with a pilot light (direct supply)

Standards

EN/ISO 13850:2006

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

AED 1,467.50

Each (ex VAT)

AED 1,540.88

Each (inc VAT)

Telemecanique Sensors XY2-CE Rope Pull Switch, 2NO/2NC

AED 1,467.50

Each (ex VAT)

AED 1,540.88

Each (inc VAT)

Telemecanique Sensors XY2-CE Rope Pull Switch, 2NO/2NC
Stock information temporarily unavailable.

Technical Document

Specifications

Normal State Configuration

2NO/2NC

Series

XY2-CE

Range

Preventa

Maximum AC Voltage

300V

Maximum Current

10A

Country of Origin

Morocco

Product details

Telemecanique XY2CE & XY2CB Emergency Stop Rope Pull Switches

These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the trip wire breaking.

Switches incorporate positive opening operation contacts, the tripping of the switch being made with positive action
The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling
Incorporates a reset button, which re-closes the safety contact(s), restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch
Recommended distance between cable supports is 15m (for model XY2-CB30 a distance of 20m is recommended)
The XY2 CE1A296 comes with a pilot light (direct supply)

Standards

EN/ISO 13850:2006