Specifications
Brand
TurckNumber of Channels
1
Module Type
HART Isolating Transducer
Barrier Type
Galvanic Barrier
Output Signal Type
Current
Maximum Voltage
250V
Interface
HART
Hazardous Area Certification
ATEX, IECEx
Input Signal Type
Current
Supply Voltage
24V dc
Minimum Operating Temperature
-25°C
Maximum Operating Temperature
+70°C
Safety Voltage Maximum
250 V
Series
IM
Operating Temperature Range
-25 → +70°C
Country of Origin
Germany
Product details
Isolating Transducer
Professional range of galvanically isolated Isolating transducers for the transmission of a unattenuated output signal to the non-Ex area. This series is environmentally versatile and comes with a variety of approvals, meaning the IM signal conditioning series can be installed in a comprehensive range of applications
Features of the IM Isolating Transducer Series
Suitable for Zone 2 installation
Safety Integrity Level (SIL) 2
Removable screw-termination terminal blocks, with 2mm test box
Complete galvanic isolation
4 - 20mA input & output circuits
Supports HART communication and 2-wire active & passive 3-wire transmitters
Connection for HART handheld unit supported
Standards
ATEX, IECEx, FM, UL, GOST
Turck Banner DIN Rail Mounting
Stock information temporarily unavailable.
Please check again later.
AED 1,644.45
Each (ex VAT)
AED 1,726.67
Each (inc. VAT)
1
AED 1,644.45
Each (ex VAT)
AED 1,726.67
Each (inc. VAT)
1
Technical Document
Specifications
Brand
TurckNumber of Channels
1
Module Type
HART Isolating Transducer
Barrier Type
Galvanic Barrier
Output Signal Type
Current
Maximum Voltage
250V
Interface
HART
Hazardous Area Certification
ATEX, IECEx
Input Signal Type
Current
Supply Voltage
24V dc
Minimum Operating Temperature
-25°C
Maximum Operating Temperature
+70°C
Safety Voltage Maximum
250 V
Series
IM
Operating Temperature Range
-25 → +70°C
Country of Origin
Germany
Product details
Isolating Transducer
Professional range of galvanically isolated Isolating transducers for the transmission of a unattenuated output signal to the non-Ex area. This series is environmentally versatile and comes with a variety of approvals, meaning the IM signal conditioning series can be installed in a comprehensive range of applications
Features of the IM Isolating Transducer Series
Suitable for Zone 2 installation
Safety Integrity Level (SIL) 2
Removable screw-termination terminal blocks, with 2mm test box
Complete galvanic isolation
4 - 20mA input & output circuits
Supports HART communication and 2-wire active & passive 3-wire transmitters
Connection for HART handheld unit supported
Standards
ATEX, IECEx, FM, UL, GOST