Technical Document
Specifications
Brand
HOBUTDisplay Type
No Display
Number of Phases
3
Depth
59mm
Meter Accuracy
0.1 (Active) %, 0.1 (Frequency) %, 0.1 (Reactive Energy) %, 0.2 (Parameters Unless Stated) %, 0.5 (Power Factor) %
Maximum Temperature
+60°C
Approvals
BS 4889, BSEN 60688, CE, cUL, EN 61010-1, EN 61326-2, IEC 1036, IEC 359, IEC 60044-1, IEC 688, IEC 801.EN 55020, UL
Maximum Measurement
330 (L-N) V, 440 (L-L) V
Measurement Range
100 → 330 (L-N) V, 100 → 440 (L-L) V
Minimum Measurement
100 (L-L) V, 100 (L-N) V
Series
C-TRAN
Country of Origin
United Kingdom
Product details
C-TRAN 3 Phase CT with In-built Power Meter
The C-Tran is a combined 3 phase multi function AC power transducer and a 3 phase current transformer in one. The meter is fully programmable through either of the two communication ports. The C-Tran can replace traditional multi function meters and 3 separate current transformers with this all-in-one product with RS485 output.
RS485 output
Non-volatile EEPROM memory for storing energy registers, current and voltage ratios and calibrated data
2 communication ports
Accuracy class 0.2 to IEC688
Multiple installation options
3 phase current options; 100A (914-5357), 160A (914-5351) and 250A (914-5360)
Communication Ports
Port 1:
The port has a fixed data format that can also retrieve measurements and set the transducer operating parameters. Only the baud rate and endian format can be changed on this port.
Port 2:
The port is used as the main communication port. It uses Modbus protocol to retrieve measurements and change the transducer operating parameters. It also enables the connection of a host computer, PLC, RTU or Data logger.
Parameters measured:
Phase Voltage (V)
Line Voltage (V)
Phase Current (I)
Frequency (Hz)
Active Power Per Phase (W)
System Active Power (W)
Reactive Power Per Phase (VAr)
System Reactive Power (VAr)
Apparent Power Per Phase (VA)
System Apparent Power (VA)
Import Active Power (W.h)
Import Reactive Power (VAr.h)
Apparent Energy (VA.h)
System Power Factor (P.F.)
Amp Demand (Ad)
Maximum Amp Demand (Max.Ad)
Import Watt Demand (Wd)
Maximum Watt Demand Import (Max.Wd)
VA Demand (VAd)
Maximum VA Demand (Max. VAd)
Neutral Current
Hours Run—Voltage based
Stock information temporarily unavailable.
Please check again later.
AED 800.20
Each (ex VAT)
AED 840.21
Each (inc. VAT)
1
AED 800.20
Each (ex VAT)
AED 840.21
Each (inc. VAT)
1
Technical Document
Specifications
Brand
HOBUTDisplay Type
No Display
Number of Phases
3
Depth
59mm
Meter Accuracy
0.1 (Active) %, 0.1 (Frequency) %, 0.1 (Reactive Energy) %, 0.2 (Parameters Unless Stated) %, 0.5 (Power Factor) %
Maximum Temperature
+60°C
Approvals
BS 4889, BSEN 60688, CE, cUL, EN 61010-1, EN 61326-2, IEC 1036, IEC 359, IEC 60044-1, IEC 688, IEC 801.EN 55020, UL
Maximum Measurement
330 (L-N) V, 440 (L-L) V
Measurement Range
100 → 330 (L-N) V, 100 → 440 (L-L) V
Minimum Measurement
100 (L-L) V, 100 (L-N) V
Series
C-TRAN
Country of Origin
United Kingdom
Product details
C-TRAN 3 Phase CT with In-built Power Meter
The C-Tran is a combined 3 phase multi function AC power transducer and a 3 phase current transformer in one. The meter is fully programmable through either of the two communication ports. The C-Tran can replace traditional multi function meters and 3 separate current transformers with this all-in-one product with RS485 output.
RS485 output
Non-volatile EEPROM memory for storing energy registers, current and voltage ratios and calibrated data
2 communication ports
Accuracy class 0.2 to IEC688
Multiple installation options
3 phase current options; 100A (914-5357), 160A (914-5351) and 250A (914-5360)
Communication Ports
Port 1:
The port has a fixed data format that can also retrieve measurements and set the transducer operating parameters. Only the baud rate and endian format can be changed on this port.
Port 2:
The port is used as the main communication port. It uses Modbus protocol to retrieve measurements and change the transducer operating parameters. It also enables the connection of a host computer, PLC, RTU or Data logger.
Parameters measured:
Phase Voltage (V)
Line Voltage (V)
Phase Current (I)
Frequency (Hz)
Active Power Per Phase (W)
System Active Power (W)
Reactive Power Per Phase (VAr)
System Reactive Power (VAr)
Apparent Power Per Phase (VA)
System Apparent Power (VA)
Import Active Power (W.h)
Import Reactive Power (VAr.h)
Apparent Energy (VA.h)
System Power Factor (P.F.)
Amp Demand (Ad)
Maximum Amp Demand (Max.Ad)
Import Watt Demand (Wd)
Maximum Watt Demand Import (Max.Wd)
VA Demand (VAd)
Maximum VA Demand (Max. VAd)
Neutral Current
Hours Run—Voltage based