Technical Document
Specifications
Number of Cells
1
Terminal Contact Type
Coil Spring
Terminal Contact Material
Spring Steel
For Battery Size
A23, AAA, N
Brand
KeystoneCountry of Origin
United States
Product details
CM-EFS Voltage Window Monitoring Relay - Single Phase AC/DC
The voltage window monitoring relay CM-EFS.2 can be used for the simultaneous monitoring of over- (>U) and undervoltages (
The voltage to be monitored (measured value) is applied to terminals B-C. Open- or closed-circuit principle as well as an adjustable ON A or OFF tripping delay are configurable.
Monitoring of DC- and AC voltages from 3-600 V
RMS measuring principle
One device includes 4 measuring ranges: 3-30V; 6-60V; 30-300V; 60-600V
Over- and undervoltage monitoring
ON-or OFF-delay configurable
Open- or closed circuit principle configurable
Latching function configurable
Thresholds for Umin and Umax adjustable
Fixed hysteresis of 5%
Tripping delay TV adjustable 0; 0.1-30s
1x2 c/o contacts (common signal) or 2x1 c/o contact (separate signals for Umin and Umax)
22.5mm width
3 LED's for status indication
Stock information temporarily unavailable.
Please check again later.
AED 8.15
Each (In a Pack of 10) (ex VAT)
AED 8.558
Each (In a Pack of 10) (inc VAT)
10
AED 8.15
Each (In a Pack of 10) (ex VAT)
AED 8.558
Each (In a Pack of 10) (inc VAT)
10
Buy in bulk
quantity | Unit price | Per Pack |
---|---|---|
10 - 190 | AED 8.15 | AED 81.50 |
200 - 590 | AED 7.70 | AED 77.00 |
600+ | AED 7.35 | AED 73.50 |
Technical Document
Specifications
Number of Cells
1
Terminal Contact Type
Coil Spring
Terminal Contact Material
Spring Steel
For Battery Size
A23, AAA, N
Brand
KeystoneCountry of Origin
United States
Product details
CM-EFS Voltage Window Monitoring Relay - Single Phase AC/DC
The voltage window monitoring relay CM-EFS.2 can be used for the simultaneous monitoring of over- (>U) and undervoltages (
The voltage to be monitored (measured value) is applied to terminals B-C. Open- or closed-circuit principle as well as an adjustable ON A or OFF tripping delay are configurable.
Monitoring of DC- and AC voltages from 3-600 V
RMS measuring principle
One device includes 4 measuring ranges: 3-30V; 6-60V; 30-300V; 60-600V
Over- and undervoltage monitoring
ON-or OFF-delay configurable
Open- or closed circuit principle configurable
Latching function configurable
Thresholds for Umin and Umax adjustable
Fixed hysteresis of 5%
Tripping delay TV adjustable 0; 0.1-30s
1x2 c/o contacts (common signal) or 2x1 c/o contact (separate signals for Umin and Umax)
22.5mm width
3 LED's for status indication